热法磷酸水化塔热平衡及热利用效率分析计算
收稿日期: 2020-05-18
网络出版日期: 2020-12-01
基金资助
江苏省研究生科研与实践创新计划项目(SJX18_0966)
Analysis and calculation of heat balance and heat utilization efficiency in hydration tower of thermal phosphoric acid
Received date: 2020-05-18
Online published: 2020-12-01
王政伟 , 李晓博 , 梁慧力 , 李佩萤 . 热法磷酸水化塔热平衡及热利用效率分析计算[J]. 无机盐工业, 2020 , 52(11) : 95 -98 . DOI: 10.11962/1006-4990.2019-0645
Aiming at the problem that the waste heat of the hydration tower of two-step thermal phosphoric acid process was notutilized,a waste heat utilization scheme and device for the hydration tower was proposed.According to the energy balance,the energy flow chart of the hydration tower was obtained,and the heat balance equation of the hydration tower was established.The calculation formula of the thermal efficiency positive and negative balance of the hydration tower,the heat exchange amount in the tower,the steam production and various heat losses were obtained.Technical measures to im-prove the heat utilization efficiency of the hydration tower were analyzed and an example calculation was conducted.
[1] | 杨亚斌, 梅毅. 热法磷酸生产副产蒸汽的回收利用技术[J]. 无机盐工业, 2017,40(2):45-46. |
[2] | 雷波, 梅毅. 热法磷酸的发展趋势与研究方向[J]. 云南化工, 2007,34(6):64-68 |
[3] | 王政伟, 李晓博 等.热法磷酸水化过程的余热利用装置:中国, 201910302818.1[P]. 2019 -04-16 |
[4] | 王政伟, 李园园, 雷斌. 热法磷酸特种燃磷塔热平衡及热利用效率分析计算[J]. 无机盐工业, 2017,49(4):71-75. |
[5] | 王政伟, 陈非凡, 许鑫, 等. 具有过热器的特种燃磷塔传热特性分析及计算[J]. 无机盐工业, 2018,50(10):74-77. |
/
〈 |
|
〉 |